Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume

Description

The power module recovered from a partial failure. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The power module recovered from a partial failure.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPowerFailResume

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.4

Alarm ID

0x0813001d

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the trap ID.
  • 136707

  • 136704

  • 136720

  • 136712

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

The power module works properly.

Possible Causes

The power module recovered from a partial failure.

Procedure

  1. This trap message is informational only, and no action is required.