Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.68 hwMplsDynamicLabelThresholdExceedClear

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.68 hwMplsDynamicLabelThresholdExceedClear

Description

The dynamic label usage falls from the threshold.( hwMplsDynamicLabelTotalCount=[DynamicLabelTotalCount], hwMplsDynamicLabelCurrentCount=[DynamicLabelCurrentCount], hwMplsDynamicLabelThresholdUpperLimit=[DynamicLabelThresholdUpperLimit], hwMplsDynamicLabelThresholdLowerLimit=[DynamicLabelThresholdLowerLimit])

Dynamic label usage fell below the lower threshold.

Attributes

Attributes

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMplsDynamicLabelThresholdExceedClear

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.68

Alarm ID

0x00f10044

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.67 hwMplsDynamicLabelThresholdExceed

Parameters

Parameters Description

hwMplsDynamicLabelTotalCount

Total number of dynamic labels

hwMplsDynamicLabelCurrentCount

Number of dynamic labels used

hwMplsDynamicLabelThresholdUpperLimit

Upper threshold of dynamic label usage

hwMplsDynamicLabelThresholdLowerLimit

Lower threshold of dynamic label usage

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.121.3.3

hwMplsDynamicLabelTotalCount

N/A

Impact on the System

None.

Possible Causes

Unwanted LSPs were torn down, and dynamic label usage fell below the lower threshold.

Procedure

  • This alarm message is informational only, and no action is required.