Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DAD_1.3.6.1.4.1.2011.5.25.246.1.1 hwDadConflictDetect

DAD_1.3.6.1.4.1.2011.5.25.246.1.1 hwDadConflictDetect

Description

Dual-active scenario is detected.

Stack cable faults led to stack division. A dual-active scenario occurred.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwDadConflictDetect

Trap OID

1.3.6.1.4.1.2011.5.25.246.1.1

Alarm ID

0x09a90000

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

DAD_1.3.6.1.4.1.2011.5.25.246.1.2 hwDadConflictResume

Parameters

None

VB

None

Impact on the System

If a dual-active scenario occurs, two switches with the same IP address, MAC address, and global configurations are available on the network. As a result, data forwarding is affected.

Possible Causes

Cause 1: The cable of the stack management link was removed.

Cause 2: The cable of the stack management link was faulty.

Procedure

  • Cause 1: Stack cables were removed.
    1. Check whether stack cables are removed.

      • If so, go to step 2.

      • If not, go to step 3.

    2. Reconnect the stack cables.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 2: Stack cables were faulty.
    1. Check whether the indicator on the stack member interface is working properly.

      • If so, go to step 3.

      • If not, go to step 2.

    2. Replace the stack cables.
    3. Collect traps, logs, and configurations, and contact technical support personnel.