Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.15 hwBrdTempFatalAlarm

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.15 hwBrdTempFatalAlarm

Description

The board temperature exceeded the fatal alarm threshold. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName],EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The board temperature exceeded the fatal alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBrdTempFatalAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.15

Alarm ID

0x0813000b

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.16 hwBrdTempFatalAlarmResume

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityThresholdType

Indicates the threshold type of the entity.

EntityThresholdCritical

Indicates the temperature threshold of the entity.

EntityThresholdCurrent

Indicates the current temperature.

EntityTrapFaultID

Indicates the error code: 143872.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.1 hwEntityThresholdType entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.5.1.5 hwEntityThresholdWarning entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.3

hwEntityThresholdCurrent

entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.3 hwEntityTrapFaultID

N/A

Impact on the System

The board may be powered off.

Possible Causes

The board temperature was extremely high.

Procedure

  1. Check whether the air filter of the fan is blocked.

    • If so, clean the air filter.

    • If not, go to step 2.

  2. Check whether the ambient temperature is too high.

    • If so, reduce the ambient temperature.

    • If not, go to step 3.

  3. Check whether the fan is faulty.

    • If so, rectify the fan fault.

    • If not, go to step 4.

  4. Check whether a filler panel is installed in the slot that has no board installed.

    • If so, go to step 5.

    • If not, install a filler panel in the slot.

  5. Collect traps, logs, and configurations, and contact technical support personnel.