Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

Description

A power module experienced a partial failure. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The power module partially failed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPowerRemove

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.3

Alarm ID

0x0813001d

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the trap ID.
  • 136707

  • 136704

  • 136720

  • 136712

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

A fault of the power module may cause insufficient power supply on the device. As a result, boards will be reset. Services are affected. This fault needs to be rectified.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[136707]): The sub-module of the power module failed.

  • Cause 2 (EntityTrapFaultID=[136704]): Communication failed between power and CMU.

  • Cause 3 (EntityTrapFaultID=[136720]): The power supply switch failed.

  • Cause 4 (EntityTrapFaultID=[136712]): The output current was slightly uneven.

Procedure

  • Cause 1: The sub-module of the power module failed.
    1. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 2: Communication failed between power and CMU.
    1. Remove and reinstall the power module. If the fault persists, go to step 2.
    2. Replace the power module. If the fault persists, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 3: The power supply switch failed.
    1. Manually turn on the backplane power supply switch.
  • Cause 4: The current slight share.
    1. Shorten the cable length to reduce the board power consumption. If the fault persists, go to step 2.
    2. If other power modules are not powered on, power on the power modules. If the fault persists, go to step 3.
    3. Replace the power module.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039527

Views: 69212

Downloads: 21

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next