No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RM_1.3.6.1.4.1.2011.5.25.145.6.2 rm_mib_trap_tnlgroup_down

RM_1.3.6.1.4.1.2011.5.25.145.6.2 rm_mib_trap_tnlgroup_down

Description

The status of the tunnel group changed to Down. (Destination=[IPADDR], TunnelPolicy=[STRING])

All tunnels in a tunnel group went Down.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

rm_mib_trap_tnlgroup_down

Trap OID

1.3.6.1.4.1.2011.5.25.145.6.2

Alarm ID

0x08622002

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

RM_1.3.6.1.4.1.2011.5.25.145.6.1 rm_mib_trap_tnlgroup_up

Parameters

Name Meaning

Destination

Destination address

TunnelPolicy

Tunnel policy

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.145.5.1

hwTnlDestionation

N/A

1.3.6.1.4.1.2011.5.25.145.5.2

hwTnlPolicy

N/A

Impact on the System

Services may be interrupted.

Possible Causes

Cause: the link failed or the user configurations changed.

Procedure

  1. After a tunnel group fails, the device sends an alarm with information about the destination address and tunnel policy to inform users of the tunnel group failure. You can run the display this command in the tunnel policy view to check whether tunnel-policy tunnel-policy-name is displayed.
  2. If a binding tunnel policy is used, run the display interface tunnel interface-number command to check whether the bound tunnel interface is Up.

    • If the bound tunnel interface is Up, go to 3.
    • If the bound tunnel interface is not Up, configure the TE interface.

  3. Collect the trap information, log information, and configuration information, and then contact technical support personnel technical support personnel.
  4. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039527

Views: 91387

Downloads: 21

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next