DEVM/2/hwBrdTempAlarm_active
Message
DEVM/2/hwBrdTempAlarm_active: The board temperature exceeded the upper alarm threshold.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])
Parameters
Parameter Name | Parameter Meaning |
---|---|
EntPhysicalIndex | Indicates the entity index. |
EntPhysicalName | Indicates the entity name. |
EntityThresholdType | Indicates the threshold type of the entity. |
EntityThresholdCritical | Indicates the temperature threshold of the entity. |
EntityThresholdCurrent | Indicates the current temperature. |
EntityTrapFaultID | Indicates the error code.
|
Reason | Indicates a possible cause. |
Possible Causes
Cause 1 (EntityTrapFaultID=[143617]): The board temperature was too high.
Cause 2 (EntityTrapFaultID=[143616]): The card temperature was too high.
Procedure
- Check whether the air filter of the fan is blocked.
If so, clean the air filter.
If not, go to step 2.
- Check whether the ambient temperature is too high.
If so, reduce the ambient temperature.
If not, go to step 3.
- Check whether the fan is faulty.
If so, rectify the fan fault.
If not, go to step 4.
- Collect traps, logs, and configurations, and contact technical support personnel.