Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG/4/hwFabricLinkLimitAlarm_active

STACKMNG/4/hwFabricLinkLimitAlarm_active

Message

STACKMNG/4/hwFabricLinkLimitAlarm_active: The number of current fabric links is smaller than the number of fabric links configured. (hwStackFabricPort=[hwStackFabricPort], hwFabricCurrentLinkNum=[hwFabricCurrentLinkNum], hwFabricConfiguredLinkNum=[hwFabricConfiguredLinkNum])

Description

The number of available fabric port links is smaller than the configured alarm threshold.

Parameters

Parameter Name Parameter Meaning

hwStackFabricPort

Indicates the fabric port number.

hwFabricCurrentLinkNum

Indicates the number of current links.

hwFabricConfiguredLinkNum

Indicates the configured alarm threshold.

Possible Causes

Cause 1: The networking is improper or the configured alarm threshold for the number of available fabric port links is high.

Cause 2: The protocol state of the port is Down.

Cause 3: The fabric port link is faulty.

Procedure

  1. Run the display stack link-state last-down-reason command to check whether a fabric port link is Down.

    • If a fabric port link is Down, rectify the fault according to the reason.
    • If all fabric port links are Up, go to step 2.

  2. Increase the number of fabric port links or run the fabric min-links threshold alarm-threshold command to reduce the alarm threshold for the number of available fabric port links.