Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PICDRIVER/4/WUnitOfPortSts

PICDRIVER/4/WUnitOfPortSts

Message

PICDRIVER/4/WUnitOfPortSts: Optical module exception(portName=[PortName],reason=[StatusChanged],value=[Value])

Description

The temperature, bias current, or voltage of the optical module exceeds the alarm threshold.

Parameters

Parameter Name Parameter Meaning

portName

Indicates the interface name.

reason

Indicates the status change. The value can be:

  • 22: The temperature was too high.
  • 23: The temperature was too low.
  • 24: The temperature recovered.
  • 25: The bias current sent by the optical module was too high.
  • 26: The bias current sent by the optical module was too low.
  • 27: The bias current sent by the optical module recovered.
  • 31: The voltage was too high.
  • 32: The voltage was too low.
  • 33: The voltage recovered.

value

Indicates the current temperature, bias current, or voltage.

Possible Causes

Cause 1: The temperature of the optical module was too high.

Cause 2: The temperature of the optical module was too low.

Cause 3: The bias current of the optical module was too high.

Cause 4: The bias current of the optical module was too low.

Cause 5: The voltage of the optical module was too high.

Cause 6: The voltage of the optical module was too low.

Procedure

  • Collect traps, logs, and configurations, and contact technical support personnel.