Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPFV3/4/OSPFV3_CONFLICT_ROUTERID_INTRA

OSPFV3/4/OSPFV3_CONFLICT_ROUTERID_INTRA

Message

OSPFV3/4/OSPFV3_CONFLICT_ROUTERID_INTRA: OSPFv3 router ID conflict is detected in intra-area.(ProcessId=[ProcessId], RouterId=[RouterId], AreaId=[AreaId])

Description

A router ID conflict was detected in an OSPFv3 area.

Parameters

Parameter Name Parameter Meaning

ProcessId

Indicates the ID of a process.

RouterId

Indicates the router ID of a router.

AreaId

Indicates the ID of an area.

Possible Causes

At least two indirectly routers were configured with the same router ID, causing router LSAs to be constantly refreshed. As a result, route flapping occurs.

Procedure

  • Modify the router IDs of the routers to ensure that each router in the area has a unique router ID.