TRILL/6/TRILL_RECV_SMALL_RLT_LSP
Message
TRILL/6/TRILL_RECV_SMALL_RLT_LSP: TRILL receive LSP with small Remaining Lifetime. (trillSysInstance=[hwTrillInstanceID], ifIndex=[ifIndex], ifName=[IfName], trillAdjSysID=[hwTrillSysID], trillPduLSPid=[hwTrillPduLspId], trillRemainingLifetime=[hwTrillRemainingLifetime])
Parameters
Parameter Name | Parameter Meaning |
---|---|
trillSysInstance |
TRILL process ID |
ifIndex |
Interface index |
ifName |
Name of the interface that received the LSP |
trillAdjSysID |
System ID of the neighbor that sent the LSP |
trillPduLSPid |
LSP ID |
trillRemainingLifetime |
Remaining Lifetime of the LSP |
Possible Causes
The local device received an LSP generated by another device, and the LSP was newer than the corresponding LSP stored locally. In addition, the Remaining Lifetime of the LSP was non-zero and less than 60s.
Procedure
- Run the display trill lsdb command to check the Holdtime field. This field indicates the value of Remaining Lifetime.
Check whether the value is less than 60s.
- Check whether the Remaining Lifetime of the LSP is less than 60s when the neighbor sent it.
- Check whether the LSP is an attack packet.
- Check whether the Remaining Lifetime was changed manually.
- If the Remaining Lifetime of the LSP is less than 60s, check whether
it was changed manually.
- If the Remaining Lifetime was changed manually, no action is required, and go to Step 3.
- If the Remaining Lifetime was not changed manually, go to Step 2.
- If the Remaining Lifetime of the LSP is not less than 60s, go to Step 2.
- Collect alarm information and configuration information, and then contact technical support personnel.
- End.