Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPFV3/4/OSPFV3_TRAP_RESET_HELP_STAT_CHNG

OSPFV3/4/OSPFV3_TRAP_RESET_HELP_STAT_CHNG

Message

OSPFV3/4/OSPFV3_TRAP_RESET_HELP_STAT_CHNG: The neighbor exits from the restart helper state. (RouterId=[RouterId], NbrIfIndex=[NbrIfIndex], NbrIfInstId=[NbrIfInstId], NbrRtrId=[NbrRtrId], NbrRestartHelperStatus=[NbrRestartHelperStatus], NbrRestartHelperAge=[NbrRestartHelperAge], NbrRestartHelperExitReason=[NbrRestartHelperExitReason])

Description

The GR helper status of an OSPFv3 neighbor changed.

Parameters

Parameter Name Parameter Meaning

RouterId

Router ID of the local device.

NbrIfIndex

IP address of the non-virtual interface.

NbrIfInstId

Router ID of the neighbor interface.

NbrRtrId

Status of the neighbor interface.

NbrRestartHelperStatus

New helper status.

NbrRestartHelperAge

Remaining time for completing GR.

NbrRestartHelperExitReason

Reason of exiting from the helper status.

Possible Causes

During GR, the GR helper status of the router changed.

Procedure

  1. Perform the following operations as required.

    • If the alarm was caused by manual master/slave switchover or OSPF process restart by GR, go to Step 3.

    • If the alarm was generated without any manual operation, go to Step 2.

  2. Contact technical support personnel technical support personnel.
  3. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602