No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IGMP/6/ERR_VER_PKT_IGMP

IGMP/6/ERR_VER_PKT_IGMP

Message

IGMP/6/ERR_VER_PKT_IGMP:In the VPN instance, the received IGMP Query packet is ignored because the IGMP version of the packet is different from that configured on the interface. (VPNName=[VPNName], IfName=[IfName], IfAddr=[IfAddr], SrcAddr=[SrcAddr], RcvVersion=[RcvVersion], IfVersion=[IfVersion])

Description

The version of IGMP configured on the interface was different from that of the received IGMP Query packet.

Parameters

Parameter Name Parameter Meaning
VPNName Name of a VPN instance
IfName Name of an interface
IfAddr Interface address
SrcAddr Source address
RcvVersion Version of the received IGMP Query packet
IfVersion Version of IGMP configured on the interface, which can be one of the following:
  • IGMPv1

  • IGMPv2

  • IGMPv3

Possible Causes

The IGMP Query packet was invalid or its version of IGMP was higher than that configured on the interface.

Procedure

  • This log message is informational only, and no action is required.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602

Views: 124674

Downloads: 90

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next