Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IPFPM/4/hwIpfpmDcpFlowConflict

IPFPM/4/hwIpfpmDcpFlowConflict

Message

IPFPM/4/hwIpfpmDcpFlowConflict:The flow conflicts with another existing flow.(TestInstanceId=[InstanceId], FlowType=[FlowType], ConflictInstId=[ConflictInstanceId], ConflictFlowType=[ConflictFlowType])

Description

The flow characteristics of a specified target flow in an IP FPM instance conflict with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

Parameters

Parameter Name Parameter Meaning

TestInstanceId

IP FPM instance ID

FlowType

Target flow type

ConflictInstId

IP FPM instance ID in conflict

ConflictFlowType

Target flow type in conflict

Possible Causes

The flow characteristics of a specified target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP, causing a flow conflict alarm.

Procedure

  1. Check whether the flow characteristics of a newly configured target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Check the cause of the flow characteristics overlap and resolve the problem. Then check whether the alarm persists.

    • If so, go to Step 3.
    • If not, go to Step 4.

  3. Collect log information and configuration information, and then contact technical support personnel.
  4. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602