No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM/4/CRT_SG_FAIL

PIM/4/CRT_SG_FAIL

Message

PIM/4/CRT_SG_FAIL:In the VPN instance, PIM-SSM failed to create the (S,G) entry in the multicast routing table. (VPNName=[VPNName], GrpAddr=[GrpAddr], SrcAddr=[SrcAddr])

Description

Failed to create the (S, G) entry.

Parameters

Parameter Name Parameter Meaning
VPNName Indicates the name of a VPN instance.
GrpAddr Indicates the group address.
SrcAddr Indicates the source address.

Possible Causes

Cause 1: The multicast source was filtered out.

Cause 2: The memory was not enough.

Cause 3: The current route entries reached the upper limit.

Procedure

  • Cause 1: The multicast source was filtered out.
    1. Run the display acl { acl-number | name acl-name | all } command to ensure the (S, G) will not be filtered out, that is, ensure that the source address and group address will not be denied by the ACL applied to multicast.

      • If the fault is rectified, proceed to Step 3.
      • If the fault persists, proceed to Step 2.

    2. Collect log messages and contact technical support personnel.
    3. End.
  • Cause 2: The memory was not enough.
    1. Ensure that system memory is enough.

      • If the fault is rectified, proceed to Step 3.
      • If the fault persists, proceed to Step 2.

    2. Collect log messages and contact technical support personnel.
    3. End.
  • Cause 3: The current route entries reached the upper limit.
    1. Run the display pim routing-table and display multicast routing-table commands to check the total number of PIM entries and multicast routing entries. Ensure that the total number does not reach the upper limit specified in the current PIM version.

      • If the fault is rectified, proceed to Step 3.
      • If the fault persists, proceed to Step 2.

    2. Collect log messages and contact technical support personnel.
    3. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602

Views: 122097