Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ND/4/hwInterfaceNDThresholdExceed_clear

ND/4/hwInterfaceNDThresholdExceed_clear

Message

ND/4/hwInterfaceNDThresholdExceed_clear: The number of ND entries was restored to the threshold of interface. (entPhysicalIndex=[entPhysicalIndex], Slotname=[slotname], InterfaceName=[InterfaceName], Threshold=[Threshold], Number of dynamic ND entries=[DynEntries], Number of static ND entries=[StatEntries]).

Description

The number of ND entries on an interface fell below the 70% of alarm threshold.

Parameters

Parameter Name Parameter Meaning

entPhysicalIndex

Index of the board that reports the clear alarm

Slotname

Name of the board that reports the clear alarm

InterfaceName

Name of the interface that reports the clear alarm

Threshold

Clear alarm threshold

Number of dynamic ND entries

Number of dynamic ND entries on the interface that reports the clear alarm

Number of static ND entries

Number of static ND entries on the interface that reports the clear alarm

Possible Causes

Dynamic ND entries aged, or ND entries were manually deleted from the interface.

Procedure

  • This trap message is informational only, and no action is required.