Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLKSYNC/4/PTPTIMESTAMPUNCHANGE

CLKSYNC/4/PTPTIMESTAMPUNCHANGE

Message

CLKSYNC/4/PTPTIMESTAMPUNCHANGE: The timestamp state is abnormal.(State=[State])

Description

The timestamp status was abnormal.

Parameters

Parameter Name Parameter Meaning

State

Timestamp status. The value 0 indicates that the timestamp status is abnormal.

Possible Causes

The received timestamp remained unchanged.

Procedure

  1. Run the display ptp interface interface-type interface-number command to check whether the number of Sync messages received by the current interface remains unchanged.

    (1) If so, go to step 2.

    (2) If not, go to step 3.

  2. Check whether the link fails. If the link fails, repair the link.
  3. Contact technical support.
  4. End.