Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LACP/2/hwLacpPartialLinkLoss_active

LACP/2/hwLacpPartialLinkLoss_active

Message

LACP/2/hwLacpPartialLinkLoss_active: Link bandwidth lost partly. (TrunkIndex=[TrunkIndex], TrunkIfIndex=[TrunkIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], Reason=[Reason])

Description

The bandwidths of a link were partially lost.

Parameters

Parameter Name Parameter Meaning

TrunkIndex

Indicates the index of a Trunk.

TrunkIfIndex

Indicates the index of a Trunk interface.

TrunkId

Indicates the ID of a Trunk interface.

TrunkName

Indicates the name of a Trunk interface.

Reason

Indicates the cause of the alarm.

Possible Causes

Cause: The number of the Eth-trunk member links that can be selected is smaller than the lower threshold value.

Procedure

  1. Run the display interface brief command to check whether the interface is Down.

    • If so, go to Step 2.
    • If not, go to Step 4.

  2. Run the undo shutdown command to check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 3.

  3. Check whether the physical link is faulty.

    • If so, go to Step 7.
    • If not, go to Step 4.

  4. Run the display eth-trunk [ trunk-id [ interface interface-type interface-number | verbose ] | brief ] command to check whether there are member interfaces in the LAG.

    • If so, go to Step 5.
    • If not, go to Step 8.

  5. Run the display trunkmembership eth-trunk trunk-id command to check whether the lower threshold for Eth-Trunk member links is set in the LAG; whether the number of Eth-Trunk member links that are successfully negotiated is smaller than the lower threshold for the Eth-Trunk member links that can be Up.

    • If so, go to Step 6.
    • If not, go to Step 9.

  6. In the Eth-Trunk interface view, run the least active-linknumber link-number command to correctly set the lower threshold of Trunk member links that can be Up. Then, check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 9.

  7. Repair the physical link and then check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 4.

  8. Run the eth-trunk trunk-id command in the interface view and add the current Ethernet interface to the Eth-Trunk interface as required. Then, check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 5.

  9. Collect information about configurations, trap messages, and log messages, and then contact technical support personnel.
  10. End.