Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FCOE/4/FCOE_VFPORT_CONNECT_FAIL

FCOE/4/FCOE_VFPORT_CONNECT_FAIL

Message

FCOE/4/FCOE_VFPORT_CONNECT_FAIL: The number of VF_Ports has already reached the maximum. (VF_Port quantity= [vfPortNum])

Description

The number of VF_Ports of the FCoE interface has reached the maximum.

Parameters

Parameter Name Parameter Meaning

vfPortNum

Number of VF_Ports.

Possible Causes

After the number of VF_Ports of the FCoE interface has reached the maximum, some ENodes still send login requests to the FCF.

Procedure

  • Adjust the networking and reduce the number of ENodes.