Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLKM/4/hwClockSourceSwitch

CLKM/4/hwClockSourceSwitch

Message

CLKM/4/hwClockSourceSwitch: Clock source switch notification.(hwClockChassisId = [hwClockChassisId], hwClockPllId = [hwClockPllId], hwClockLastSourceName = [hwClockLastSourceName],hwClockCurSourceName = [hwClockCurSourceName], hwClockSrcSelChassisIndex = [hwClockSrcSelChassisIndex], hwClockSrcSelType = [hwClockSrcSelType],hwClockSrcSelMode = [hwClockSrcSelMode])

Description

The clock source changed.

Parameters

Parameter Name Parameter Meaning
hwClockSrcSelChassisIndex

Index of the chassis where the clock source resides.

hwClockSrcSelType

Clock source type:

  • 1: bits(1)
  • 2: ptp(2)
  • 3: interface(3)
hwClockChassisId ID of the chassis where the clock source resides.
hwClockPllId

Clock source type ID.

hwClockLastSourceName Last clock source name.
hwClockCurSourceName Current clock source name.
hwClockSourceSelMode

Clock source selection mode:

  • auto(0): automatic clock source selection
  • manual(1): manual clock source selection
  • force(2): forcible clock source selection

Possible Causes

1: Attributes of a clock device on the network were changed, which caused the switchover of the master clock.

2: An associated link failed or an associated interface became Down, which caused the switchover of the master clock.

3: The clock source was manually switched in manual or forcible clock source selection.

Procedure

  1. Run the display clock source command to check the operating mode of the clock source.

    • If the operating mode is free, the clock source is in free state. Then, go to step 6.

    • If the operating mode is hold, the clock source is in hold state. Then, go to step 6.

    • If the operating mode is normal, go to step 2.

  2. Run the display clock config command to check the clock source selection mode.

    • If the clock source selection mode is manual or forcible, the clock source is switched forcibly. Then, go to step 6.

    • If the clock source selection mode is automatic, go to step 3.

  3. Run the display clock source command to check whether the clock source is in normal state.

    • If so, go to step 4.

    • If not, go to step 5.

  4. Run the display clock source command to check whether the attributes of the clock source are changed.

    • If so, go to step 6.

    • If not, go to step 5.

  5. Collect alarm information, log information, and configuration of the device, and contact technical support.
  6. End.