Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET/2/hwPhysicalAdminIfDown_active

IFNET/2/hwPhysicalAdminIfDown_active

Message

IFNET/2/hwPhysicalAdminIfDown_active: The physical manage interface physical status changes to down.(ifName=[ifName], OperStatus=[ifOperStatus])

Description

The physical status of a management interface went Down.

Parameters

Parameter Name Parameter Meaning

ifName

Name of the physical management interface

ifOperStatus

Status of the physical management interface

Possible Causes

The physical link status of the management interface went Down.

Procedure

  1. Check whether the physical link of the interface is properly connected, including whether hardware such as the network cable and optical module is in loose connection or disconnected.

    • If the physical link is not connected properly, rectify the physical link connection and then check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the physical link is properly connected, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.