Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD/5/DELSESS

BFD/5/DELSESS

Message

BFD/5/DELSESS:The BFD session was deleted. (Discriminator=[ULONG], Result=[STRING], Applications=[STRING], BindIFName=[STRING], SourceIp=[STRING], PeerIp=[STRING])

Description

A BFD session was deleted.

Parameters

Parameter Name Parameter Meaning

Discriminator

Local discriminator of a session

Result

Whether a BFD session is deleted:
  • Succeeded

  • Failed

Applications

Application bound to a BFD session

BindIFName

Name of an interface bound to a BFD session

SourceIp

Source IP address

PeerIp

Destination IP address

Possible Causes

  1. The BFD session was manually deleted.
  2. When the dynamic BFD session was in the DetectDown or NeighborDown state, APP instructed BFD to delete the session.

Procedure

  1. Perform either of the following operations:

    • If the deleted BFD session is a static session, no further action is required.
    • If the deleted BFD session is a dynamic session, go to Step 2.

  2. Run the ping command to check whether the link monitored by the BFD session is working properly.

    • If the link monitored by the BFD session is working properly, contact technical support personnel.
    • If the link monitored by the BFD session is not working properly, rectify the link fault.

  3. End.