Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG/4/STACK_MEMPORT_LINK_DOWN

STACKMNG/4/STACK_MEMPORT_LINK_DOWN

Message

STACKMNG/4/STACK_MEMPORT_LINK_DOWN: The stack member port's link state is down. (hwStackLocalIfName=[hwStackLocalIfName])

Description

The physical member interfaces of the stack interface became Down.

Parameters

Parameter Name Parameter Meaning
hwStackLocalIfName

Indicates the name of the local interface.

Possible Causes

Cause 1: Physical member interfaces of the stack interface became Down.

Cause 2: Physical member interfaces of the stack interface were shut down.

Cause 3. The stack link was faulty.

Procedure

  1. Check the connection and validity of stack cables. Run the display interface brief command to check the physical status and protocol status of the stack interface.

    • If the physical status of an interface is Down, check whether the cable connected to the interface is loosened or removed.
    • If the physical status of the interface is Up, go to step 2.

  2. Check whether the shutdown command was executed on the interface. Run the interface interface-type interface-number command to enter the stack interface view, and run the display this command to check whether the shutdown configuration exists.

    • If so, run the undo shutdown command.
    • If not, go to step 3.

  3. Collect traps, logs, and configurations, and contact technical support personnel.