Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF/6/OSPF_SMOOTH

OSPF/6/OSPF_SMOOTH

Message

OSPF/6/OSPF_SMOOTH: OSPF-INFO:Smooth event happen between components. (LocalComp=[LocalComp], PeerComp=[PeerComp], ProducerName=[ProducerName], SmoothLevel=[SmoothLevel], ProcessId=[ProcessId], AreaTableId=[AreaTableId], SmoothEvent=[SmoothEvent])

Description

A smoothing event occurred between two components.

Parameters

Parameter Name Parameter Meaning

[LocalComp]

Name of the local component.

[PeerComp]

Name of the peer component.

[ProducerName]

Name of the verification producer.

[SmoothLevel]

Smoothing level.

COMP_LEVEL

Component-level smoothing.

PROC_LEVEL

Process-level smoothing.

AREA_TABLE_LEVEL

Area- or table-level smoothing.

[ProcessId]

OSPF process ID.

[AreaTableId]

OSPF area ID or routing table ID.

[SmoothEvent]

Type of a smoothing event:

  • SMOOTH_REQUEST: indicates a smoothing request event.

  • SMOOTH_DELAY: indicates a smoothing delay event.

  • SMOOTH_BEGIN: indicates a smoothing start event.

  • SMOOTH_END: indicates a smoothing end event.

Possible Causes

Cause 1: Perform the master/slave switchover.

Cause 2: Run the reset ospf process command to reset an OSPF process.

Cause 3: Sequence numbers mismatched or data was incorrect.

Cause 4: Data was incorrect.

Procedure

  • This log message is informational only, and no action is required.