No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM/3/THRESHOLD

EFM/3/THRESHOLD

Message

EFM/3/THRESHOLD:Threshold event occured. (IfIndex=[IfIndex], EventLogIndex=[EventLogIndex], EventLogTimestamp=[EventLogTimestamp], EventLogOui=[EventLogOui], EventLogType=[EventLogType], EventLogLocation=[EventLogLocation], EventLogWindowHi=[EventLogWindowHi], EventLogWindowLo=[EventLogWindowLo], EventLogThresholdHi=[EventLogThresholdHi], EventLogThresholdLo=[EventLogThresholdLo], EventLogValue=[EventLogValue], EventLogRunningTotal=[EventLogRunningTotal], EventLogEventTotal=[EventLogEventTotal], IfName=[IfName])

Description

The number of errored frames, errored codes, or errored frame seconds exceeded the set threshold within the specified period.

Parameters

Parameter Name Parameter Meaning
IfIndex Interface index.
EventLogIndex Index of ta printed log.
EventLogTimestamp Timestamp that records when an event occurred.
EventLogOui Name of an outbound interface of an event.
EventLogType Type of an event.
EventLogLocation Where the event occurs, on the local or remote end.
EventLogWindowHi High-order value of a monitoring interval.
EventLogWindowLo Low-order value of a monitoring interval.
EventLogThresholdHi High-order value of the threshold of a monitoring interval.
EventLogThresholdLo Low-order value of the threshold of a monitoring interval.
EventLogValue Number of times that a threshold-crossing event occurs.
EventLogRunningTotal Number of event occurrences.
EventLogEventTotal Number of event notifications.
IfName Interface name.

Possible Causes

Cause 1:

The user configured the efm error-code threshold 0, efm error-frame threshold 0 or efm error-frame-second threshold 0 command on the interface.

Cause 2:

The physical link became faulty, causing the error frame or error code.

Procedure

  1. Check the value of the EventLogType field in the trap:

    • 1: an errored code alarm. Then go to 2.

    • 2: an errored frame alarm. Then go to 3.

    • 3: an errored frame second alarm. Then go to 4.

  2. Run the display this command in the interface view. Check whether the efm error-code threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 6.

    • If this command is not displayed, go to 5.

  3. Run the display this command in the interface view. Check whether the efm error-frame threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 7.

    • If this command is not displayed, go to 5.

  4. Run the display this command in the interface view. Check whether the efm error-frame-second threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 8.

    • If this command is not displayed, go to 5.

  5. Check whether a physical link fails.

    • If the physical link is working properly, go to 9.

    • If the physical link fails, go to 10.

  6. Run the efm error-code threshold threshold command in the interface view to set the EFM errored code detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  7. Run the efm error-frame threshold threshold command in the interface view to set the EFM errored frame detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  8. Run the efm error-frame-second threshold threshold command in the interface view to set the EFM errored frame seconds detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  9. Rectify the physical link fault and check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  10. Collect the alarm, log, and configuration information, and then contact technical support personnel.
  11. End.