No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPFV3/6/OSPFV3_CONFLICT_ROUTERID_INTER

OSPFV3/6/OSPFV3_CONFLICT_ROUTERID_INTER

Message

OSPFV3/6/OSPFV3_CONFLICT_ROUTERID_INTER: OSPFv3 router ID conflict may have occurred in inter-area.(ProcessId=[ProcessId], RouterId=[RouterId])

Description

The router IDs of OSPFv3 devices in different areas might conflict because external routes were constantly refreshed.

Parameters

Parameter Name Parameter Meaning
ProcessId Indicates the ID of a process.
RouterId Indicates the ID of a router.

Possible Causes

At least two indirectly connected routers were configured with the same router ID, causing router LSAs to be constantly refreshed. As a result, route flapping occurs.

Procedure

  • Check why external routes flap. If the router IDs of devices in different areas conflict, modify the router IDs of these devices.