ISIS/1/isisLspSeqMaxReach_active
Message
ISIS/1/isisLspSeqMaxReach_active: The LSP sequence number has reached the maximum value. (SysInstance=[SysInstance], SysLevel=[SysLevel], LspId=[LspId])
Parameters
Parameter Name | Parameter Meaning |
---|---|
SysInstance |
ID of an IS-IS process |
SysLevel |
IS-IS level |
LspId |
LSP ID |
Procedure
- Run the timer lsp-refresh command to change the
value of the LSP refresh timer, and then run the display isis lsdb command to view the sequence number of LSPs generated by the local
device.
- If the sequence number of LSPs increases regularly, no action is required.
- If the sequence number of LSPs increases quickly, go to Step 2.
- Check whether the system IDs of other devices are the same
as that of the local device.
- If another device's system ID is the same as that of the local device, go to Step 3.
- If no other device's system ID is the same as that of the local device, go to Step 4.
- Enter the IS-IS view of the local device or other devices, and then run the network-entity command to change the system ID.
- Contact technical support personnel technical support personnel.
- End.