Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PTP/4/hwPtpExtTimePortLost_active

PTP/4/hwPtpExtTimePortLost_active

Message

PTP/4/hwPtpExtTimePortLost_active: The external Time Port status changed.(Status = [Status], ExternalTimePort = [ExternalTimePort])

Description

The external time source was lost.

Parameters

Parameter Name Parameter Meaning

Status

Port status of the external time source:

  • 1: normal(0)

  • 2: portDown(1)

ExternalTimePort

Port name of the external time source.

Possible Causes

The connection between the external time source and the local device was closed.

Procedure

  1. Run the display interface interface-type interface-name command to check whether the status of the interface connecting the device to the external time source is Up.

    • If so, go to step 2.

    • If not, troubleshoot the fault.

  2. Collect alarm information, log information, and configuration of the device, and contact technical support.
  3. End.