CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PTP/4/hwPtpFrequencyLockFail_active

PTP/4/hwPtpFrequencyLockFail_active

Message

PTP/4/hwPtpFrequencyLockFail_active: Current lock status of clock frequency synchronization failed. (hwPtpFreqLockStatus = [hwPtpFreqLockStatus])

Description

Clock frequency synchronization failed.

Parameters

Parameter Name Parameter Meaning

hwPtpFreqLockStatus

Clock frequency synchronization status:

  • 1: unlock(0)

  • 2: lock(1)

Possible Causes

Cause 1: The frequency deviation of the reference clock source was large when synchronous Ethernet was enabled.

Cause 2: Timestamps were incorrect when 1588v2 frequency synchronization was enabled.

Cause 3: The output frequency deviation of the system clock exceeded +/-10 ppm.

Procedure

  1. Run the display clock source command to check whether the Current system trace source field displays ptp.

    • If so, go to step 2.

    • If not, go to step 3.

  2. Run the display current-configuration command to check whether PTP configurations are changed.

    • If so, reconfigure PTP attributes.

    • If not, go to step 4.

  3. Run the display clock config command to check whether the clock source configuration is changed.

    • If so, reconfigure the clock source on the local end.

    • If not, go to step 4.

  4. Collect alarm information, log information, and configuration of the device, and contact technical support.
  5. End.