Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L3VPN/2/L3V_TRAP_THRE_EXCEED_clear

L3VPN/2/L3V_TRAP_THRE_EXCEED_clear

Message

L3VPN/2/L3V_TRAP_THRE_EXCEED_clear: The number of routes in the VPN instance fell below the maximum value. (VpnInstanceName=[VpnInstanceName], VpnInstanceRouteCount=[VpnInstanceRouteCount], MaxValue=[MaxValue])

Description

The number of route prefixes in the VPN instance fell below the maximum value.

Parameters

Parameter Name Parameter Meaning

VpnInstanceName

VPN instance name

VpnInstanceRouteCount

Number of route prefixes in the VPN instance

MaxValue

Maximum value of the route prefixes in the VPN instance

Possible Causes

Cause: The number of prefixes contained by the specified VPN exceeds the maximum allowed value as indicated by prefix limit command, and then the number fell below the value.

Procedure

  • This log message is informational only, and no action is required.