L3VPN/2/L3V_TRAP_THRE_EXCEED_clear
L3VPN/2/L3V_TRAP_THRE_EXCEED_clear
Message
L3VPN/2/L3V_TRAP_THRE_EXCEED_clear: The number of routes in the VPN instance fell below the maximum value. (VpnInstanceName=[VpnInstanceName], VpnInstanceRouteCount=[VpnInstanceRouteCount], MaxValue=[MaxValue])
Description
The number of route prefixes in the VPN instance fell below the maximum value.
Parameters
Parameter Name
Parameter Meaning
VpnInstanceName
VPN instance name
VpnInstanceRouteCount
Number of route prefixes in the VPN instance
MaxValue
Maximum value of the route prefixes in the VPN instance
Possible Causes
Cause: The number of prefixes contained by the specified VPN exceeds the maximum allowed value as indicated by prefix limit command, and then the
number fell below the value.
Procedure
This log message is informational only, and no action is required.