No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM/1/hwBoardFail_active

DEVM/1/hwBoardFail_active

Message

DEVM/1/hwBoardFail_active: The board partially failed. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

Description

The device partially failed.

Parameters

Parameter Name Parameter Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityType

Indicates the entity type.
  • 1: MPU
  • 2: LPU
  • 3: SFU
  • 4: subcard
  • 5: storage medium

EntityTrapFaultID

Indicates the error code.
  • 132137

  • 132120

  • 132162

  • 132128

  • 132134

  • 132107

  • 132105
  • 132103
  • 132106
  • 132096
  • 132186
  • 132189
  • 132190
  • 132205
  • 132206
  • 132207

Reason

Indicates a possible cause.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[132137]): Chip instability.

  • Cause 2 (EntityTrapFaultID=[132162]): The fan model or power supply model does not match the device.

  • Cause 3 (EntityTrapFaultID=[132128]): Board PLL instability.

  • Cause 4 (EntityTrapFaultID=[132134]): LANSWITCH chip instability.

  • Cause 5 (EntityTrapFaultID=[132107]): Phy instability.

  • Cause 6 (EntityTrapFaultID=[132120]): IIC instability.

  • Cause 7 (EntityTrapFaultID=[132106]): Flash memory failed.

  • Cause 8 (EntityTrapFaultID=[132105]): The sensor on the board was faulty.

  • Cause 9 (EntityTrapFaultID=[132103]): Board RTC fault.

  • Cause 10 (EntityTrapFaultID=[132096]): Power supply abnormal.

  • Cause 11 (EntityTrapFaultID=[132186]): The forwarding engine buffer failed.

  • Cause 12 (EntityTrapFaultID=[132189]): A data channel fault occurred on the forwarding engine.

  • Cause 13 (EntityTrapFaultID=[132190]): The forwarding engine failed.

  • Cause 14 (EntityTrapFaultID=[132205]): The HiGig link on the board failed.

  • Cause 15 (EntityTrapFaultID=[132206]): A logic error occurs in the LPM table of the forwarding engine.

  • Cause 16 (EntityTrapFaultID=[132207]): The board clock fails.

Procedure

  • Cause 1: Chip instability.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 2: The fan model or power supply model does not match the device.
    1. Replace existing fans or power modules with ones that match the device.
  • Cause 3: Board PLL instability.
    1. Reset the device. If the fault cannot be rectified, replace the device.
  • Cause 4: LANSWITCH chip instability.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 5: Phy instability.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Power off and then power on the faulty device. If the fault persists, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 6: IIC instability.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 7: Flash memory failed.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 8: The sensor on the board was faulty.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 9: Board RTC fault.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Power off and then power on the faulty device. If the fault persists, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 10: Power supply abnormal.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Power off and then power on the faulty device. If the fault persists, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 11: The forwarding engine buffer failed.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Reset the device. If the fault cannot be rectified, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 12: A data channel fault occurred on the forwarding engine.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Reset the device. If the fault cannot be rectified, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 13: The forwarding engine failed.
    1. If the faulty device is not reset or powered off and services are running normally, go to step 3.
    2. Reset the device. If the fault cannot be rectified, go to step 3.
    3. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 14: The HiGig link on the board failed.
    1. Reset the device. If the fault cannot be rectified, go to step 2.
    2. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 15: A logic error occurs in the LPM table of the forwarding engine.
    1. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 16: The board clock fails.
    1. Collect traps, logs, and configurations, and contact technical support personnel.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602