Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LDT/4/LDT_ALARM_PORTLOOPBACK_active

LDT/4/LDT_ALARM_PORTLOOPBACK_active

Message

LDT/4/LDT_ALARM_PORTLOOPBACK_active: Loopback existed on the port. (ifname=[ifname], vlan=[vlanid])

Description

A loopback occurs on the interface.

Parameters

Parameter Name Parameter Meaning

ifname

Indicates the name of the interface.

vlan

Indicates the VLAN ID.

Possible Causes

A loop occurred on the interface.

Procedure

  1. Check whether the loop is caused by incorrect network configurations or cable connections.

    • If so, remove the loop.
    • If not, go to step 2.

  2. Collect traps, logs, and configurations, and contact technical support personnel.