No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS/2/isisLspSeqThresholdExceed_active

ISIS/2/isisLspSeqThresholdExceed_active

Message

ISIS/2/isisLspSeqThresholdExceed_active: The LSP sequence number has exceeded the upper threshold value. (SysInstance=[SysInstance] , SysLevel=[SysLevel], LspId=[LspId], ThresholdValue=[ThresholdValue])

Description

The LSP sequence number exceeded the upper alarm threshold.

Parameters

Parameter Name Parameter Meaning

SysInstance

ID of an IS-IS process

SysLevel

IS-IS level

LspId

LSP ID

ThresholdValue

The upper alarm threshold of LSP sequence number

Possible Causes

The LSP sequence number exceeded the upper alarm threshold.

Procedure

  1. Run the display isis lsdb command to check the sequence numbers of locally generated LSPs.

    • If the sequence numbers increase as expected, no action is required.
    • If the sequence numbers increase too fast, go to Step 2.

  2. Run the timer lsp-refresh command in the IS-IS view to increase the LSP update interval and then run the display isis lsdb command to check the sequence numbers of locally generated LSPs.

    • If the sequence numbers increase as expected, go to Step 5.
    • If the sequence numbers increase too fast, go to Step 3.

  3. Check whether there is another device on the network with the local IS-IS System ID.

    • If such a device exists, change its system ID.
    • If no such a device exists, go to Step 4.

  4. Collect the relevant information and contact technical support personnel technical support personnel.
  5. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039602

Views: 134033

Downloads: 90

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next