Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM/2/hwPowerFail_active

DEVM/2/hwPowerFail_active

Message

DEVM/2/hwPowerFail_active: A power module experienced a partial failure.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

Description

The power module partially failed.

Parameters

Parameter Name Parameter Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the trap ID.
  • 136707

  • 136732

  • 136733

Reason

Indicates a possible cause.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[136707]): The sub-module of the power module failed.

  • Cause 2 (EntityTrapFaultID=[136732]): Airflow direction of fans in power supplies is abnormal.

  • Cause 3 (EntityTrapFaultID=[136733]): The fan inside a power module fails.

Procedure

  • Cause 1: The sub-module of the power module failed.
    1. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 2: Airflow direction of fans in power supplies is abnormal.
    1. Replace the power module. If the fault persists, collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 3: The fan inside a power module fails.
    1. Power off the faulty power module and then replace it with another one.