Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DRIVER/4/hwBoardLeaveMaster

DRIVER/4/hwBoardLeaveMaster

Message

DRIVER/4/hwBoardLeaveMaster: Board leave master state. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=[EntityTrapFaultID], Reason=Master/Slave Board Switchover.)

Description

The active device exited from the active state.

Parameters

Parameter Name Parameter Meaning
EntityPhysicalIndex Indicates the entity index.
EntPhysicalIndex Indicates the entity index.
EntPhysicalName Indicates the entity name.
EntityType Indicates the entity type.
EntityTrapFaultID Indicates the error code: 133120.
Reason Indicates a possible cause.

Possible Causes

The master/slave switchover was performed or the active device was faulty.

Procedure

  1. Check whether active/standby switchover was performed.

    • If so, no action is required.

    • If not, go to step 2.

  2. Run the display device [ slot slot-id ] command to check whether the original active device has been registered successfully.

    • If so, go to step 4.

    • If not, go to step 3.

  3. Remove and install the original active device and check whether it has been registered successfully after startup.

    • If so, go to step 4.

    • If not, go to step 5.

  4. Check whether the original active device is faulty. Check whether the active/standby switchover can be performed.

    • If so, no action is required.

    • If not, go to step 5.

  5. Collect traps, logs, and configurations, and contact technical support personnel.
Translation