No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM/1/hwOpticalUnAuthorized_active

DEVM/1/hwOpticalUnAuthorized_active

Message

DEVM/1/hwOpticalUnAuthorized_active:The optical module was not certified by Huawei Ethernet Switch.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

Description

An optical module that is not certified for Huawei Ethernet switches was installed.

Parameters

Parameter Name Parameter Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code. The error code in this alarm is 145920.

Reason

Indicates the alarm cause.

Possible Causes

An optical module that is not certified for Huawei Ethernet switches was installed. Alarms may be generated because vendor information of Huawei early delivered optical modules is not recorded.

Procedure

  • If the optical module was delivered early by Huawei, run the transceiver non-certified-alarm disable command to disable the alarm function for optical modules that are not certified for Huawei Ethernet switches.

    NOTE:

    In versions earlier than V200R001C00, after the alarm function is disabled, the generated alarms will not be automatically cleared. To clear these alarms, remove and then install the optical module.

  • If the optical module is not delivered by Huawei or not certified for Huawei Ethernet switches, replace it with one that is certified for Huawei Ethernet switches.