Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IGMP/4/QUERY_INTERVAL_NOT_CONISITENT_IGMP

IGMP/4/QUERY_INTERVAL_NOT_CONISITENT_IGMP

Message

IGMP/4/QUERY_INTERVAL_NOT_CONISITENT_IGMP:The interval of IGMP general query packet received is greater than that of current configuration. (InstanceName=[InstanceName], IfName= [IfName], QueryReceInterval=[QueryReceInterval], QueryInterval=[QueryInterval])

Description

The interval at which the switch receives IGMP general query messages is larger than the interval at which the switch sends IGMP general query messages.

Parameters

Parameter Name Parameter Meaning
InstanceName VPN instance name.
Ifname Name of the interface using which the switch receives IGMP general query messages.
QueryReceInterval Interval at which the switch receives IGMP general query messages.
QueryInterval Interval at which the switch sends IGMP general query messages.

Possible Causes

The interval at which the switch receives IGMP general query messages is larger than the interval at which the switch sends IGMP general query messages.

Procedure

  1. Check whether the interval at which the switch receives IGMP general query messages is larger than the interval at which the switch sends IGMP general query messages.

    • If the IGMP general query message receiving interval is larger, go to Step 2.
    • If the IGMP general query message receiving interval is not larger, go to Step 3.

  2. Run the igmp snooping query interval query-interval command to set a same value for the General Query message receiving and sending intervals.
  3. Collect configuration information, trap messages, and log messages, and then contact technical support personnel.