Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TRUNK/3/hwExtAllMemberDownNotify_active

TRUNK/3/hwExtAllMemberDownNotify_active

Message

TRUNK/3/hwExtAllMemberDownNotify_active: The last member interface link status changes to down. (TrunkIfIndex=[INTEGER], TrunkName=[OCTET])

Description

The last member interface of an Eth-Trunk interface in static LACP mode went Down.

Parameters

Parameter Name Parameter Meaning

TrunkIfIndex

Trunk interface index

TrunkName

Name of the Trunk interface

Possible Causes

All the member interfaces of the Eth-Trunk interface in static LACP mode were Down.

Procedure

  1. Run the display this command in the Trunk interface view to check whether the Trunk interface is shut down.

    • Y=>2

    • N=>3

  2. Run the undo shutdown command in the Trunk interface view to check whether the alarm is cleared.

    • Y=>8

    • N=>3

  3. Run the display this command in the view of each Eth-Trunk member interface to check whether the member interface is shut down.

    • Y=>4

    • N=>5

  4. Run the undo shutdown command in the member interface view to check whether the alarm is cleared.

    • Y=>8

    • N=>5

  5. Check whether the cable and optical module are loosened or dropped.

    • Y=>7

    • N=>6

  6. Connect the physical link correctly and then check whether the alarm is cleared.

    • Y=>8

    • N=>7

  7. Collect alarm information and configuration information, and then contact technical support personnel.
  8. End.