EOAM-1AG/1/UnexpectedMEGLevel_active
Message
EOAM-1AG/1/UNEXPECTEDMEGLEVEL_active:MEP received a CCM with unexpected MEG level. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId])
Description
The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.
Parameters
Parameter Name | Parameter Meaning |
---|---|
MdIndex | Index of an MD table |
MaIndex | Index of an MA table |
MdName | Name of an MD |
MaName | Name of an MA |
MepId | ID of a MEP |
Possible Causes
The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.
Procedure
- Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on both the MEP and RMEP to view the value of the Level field. Check whether the MD levels are the same.
If the MD levels are different, go to Step 2.
If the MD levels are the same, go to Step 3.
- Perform the following steps on the MEP:
- Run the undo cfm md name md-name command to delete existing MD configurations.
- Run the cfm md md-name level level command to reconfigure an MD the same as that on the RMEP.
- Collect configuration, trap messages, and log messages, and then contact technical support personnel.