Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DAD/4/hwDadPortProtocolAlarm_active

DAD/4/hwDadPortProtocolAlarm_active

Message

DAD/4/hwDadPortProtocolAlarm_active:The protocol status of the dual-active port is down.(hwDadDetectPort=[hwDadDetectPort])

Description

The protocol status of the dual-active detection (DAD) port is Down.

Parameters

Parameter Name Parameter Meaning

hwDadDetectPort

Indicates the DAD port.

Possible Causes

The DAD port is physically Down or cannot properly send or receive packets.

Procedure

  1. Run the display dual-active command to check whether the physical status of the DAD port is Up.

    • If not, troubleshoot the Down failure.

    • If so, go to step 2.

  2. Collect the trap, log, and configuration information, and then contact technical support personnel.