CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM/4/PIM_ROUTE_THRESHOLD_clear

PIM/4/PIM_ROUTE_THRESHOLD_clear

Message

PIM/4/PIM_ROUTE_THRESHOLD_clear: The number of existed routing entries falls below the global lower threshold.(LimitType=[LimitType], AddressFamily=[AddressFamily], CurrentCount=[CurrentCount], LimitCount=[LimitCount], ThresholdCount=[ThresholdCount], ReasonType=[ReasonType])

Description

The percentage ratio of created PIM entries on the device to the specified limit fell below the alarm clear threshold.

Parameters

Parameter Name Parameter Meaning

LimitType

Type of entry for which an entry number limit takes effect, which is one of the followings:
  • PIM-SM (*, G) entry
  • PIM-SM (S, G) entry
  • PIM-DM (*, G) entry
  • PIM-DM (S, G) entry
  • BIDIR-PIM (*, G) entry

AddressFamily

Address family

CurrentCount

Number of created PIM entries on the device

LimitCount

Limit on the number of PIM entries on the device

ThresholdCount

Threshold at which the alarm is generated

ReasonType

Alarm cause, which is one of the followings:
  • Entries are deleted.
  • The configuration is changed.

Possible Causes

The percentage ratio of created PIM entries on the device to the specified limit fell below the alarm clear threshold.

Procedure

  • This log message is informational only, and no action is required.