Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLKM/4/hwClockSourceFreqCheck_active

CLKM/4/hwClockSourceFreqCheck_active

Message

CLKM/4/hwClockSourceFreqCheck_active: The check of frequence abnormal notification. (hwClockSrcCfgChassisIndex = [hwClockSrcCfgChassisIndex], hwClockSrcCfgSourceTypeIndex = [hwClockSrcCfgSourceTypeIndex], hwClockSrcCfgSourceIndex = [hwClockSrcCfgSourceIndex], hwClockChassisId = [hwClockChassisId], hwClockSrcCfgFreqCheckResult = [hwClockSrcCfgFreqCheckResult], hwClockSrcCfgSourceDescr=[hwClockSrcCfgSourceDescr])

Description

Frequency deviation detection functioned abnormally.

Parameters

Parameter Name Parameter Meaning
hwClockSrcCfgChassisIndex

Index of the chassis where the clock source resides. The index is always 1 for a single chassis.

hwClockSrcCfgSourceTypeIndex

Index of the clock source type:

  • 1: bits(1)
  • 2: ptp(2)
  • 3: interface(3)
hwClockChassisId ID of the chassis where the clock source resides.
hwClockSrcCfgSourceIndex Clock source index.
hwClockSrcCfgFreqCheckResult Frequency deviation detection result.
hwClockSrcCfgSourceDescr Clock source description.

Possible Causes

Signals of the clock source were faulty.

Procedure

  1. Run the display clock source command to check the current status of the clock source.

    • If the clock source is in abnormal state, frequency deviation detection functions abnormally. Go to step 3.

    • If the clock source is in another state, go to step 2.

  2. Collect alarm information, log information, and configuration of the device, and contact technical support.
  3. End.