No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM/4/PIM_ROUTE_THRESHOLD_active

PIM/4/PIM_ROUTE_THRESHOLD_active

Message

PIM/4/PIM_ROUTE_THRESHOLD_active: The number of existed routing entries exceeded the global upper threshold.(LimitType=[LimitType], AddressFamily=[AddressFamily], CurrentCount=[CurrentCount], LimitCount=[LimitCount], ThresholdCount=[ThresholdCount], ReasonType=[ReasonType])

Description

The percentage ratio of created PIM entries on the device to the specified limit reached the alarm trigger threshold.

Parameters

Parameter Name Parameter Meaning

LimitType

Type of entry for which an entry number limit takes effect, which is one of the followings:
  • PIM-SM (*, G) entry
  • PIM-SM (S, G) entry
  • PIM-DM (*, G) entry
  • PIM-DM (S, G) entry
  • BIDIR-PIM (*, G) entry

AddressFamily

Address family

CurrentCount

Number of created PIM entries on the device

LimitCount

Limit on the number of PIM entries on the device

ThresholdCount

Threshold at which the alarm is generated

ReasonType

Alarm cause, which is one of the followings:
  • Entries are added.
  • The configuration is changed.

Possible Causes

New entries were added, the limit on the number of PIM entries on the device was changed to a smaller value, or the alarm trigger threshold was changed to a smaller value.

Procedure

  1. Run the display multicast global statistics command to check whether the alarm trigger threshold or the number limit is low.

    • If either the alarm trigger threshold or the number limit is low, go to Step 2.

    • If the alarm trigger threshold and the number limit are not low, go to Step 3.

  2. Run the multicast global limit command to modify the alarm trigger threshold or the number limit. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.

    • If the alarm persists, go to Step 3.

  3. Collect log information and configuration information, and then contact technical support personnel.
  4. End.