PIM/4/PIM_ROUTE_THRESHOLD_active
Message
PIM/4/PIM_ROUTE_THRESHOLD_active: The number of existed routing entries exceeded the global upper threshold.(LimitType=[LimitType], AddressFamily=[AddressFamily], CurrentCount=[CurrentCount], LimitCount=[LimitCount], ThresholdCount=[ThresholdCount], ReasonType=[ReasonType])
Description
The percentage ratio of created PIM entries on the device to the specified limit reached the alarm trigger threshold.
Parameters
Parameter Name | Parameter Meaning |
---|---|
LimitType |
Type of entry for which an entry number limit
takes effect, which is one of the followings:
|
AddressFamily |
Address family |
CurrentCount |
Number of created PIM entries on the device |
LimitCount |
Limit on the number of PIM entries on the device |
ThresholdCount |
Threshold at which the alarm is generated |
ReasonType |
Alarm cause, which is one of the followings:
|
Possible Causes
New entries were added, the limit on the number of PIM entries on the device was changed to a smaller value, or the alarm trigger threshold was changed to a smaller value.
Procedure
- Run the display
multicast global statistics command to check whether
the alarm trigger threshold or the number limit is low.
If either the alarm trigger threshold or the number limit is low, go to Step 2.
If the alarm trigger threshold and the number limit are not low, go to Step 3.
- Run the multicast global
limit command to modify the alarm trigger threshold
or the number limit. Then, check whether the alarm is cleared.
If the alarm is cleared, go to Step 4.
If the alarm persists, go to Step 3.
- Collect log information and configuration information, and then contact technical support personnel.
- End.