Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM/2/hwFanFail_active

DEVM/2/hwFanFail_active

Message

DEVM/2/hwFanFail_active: The fan partially failed. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

Description

The fan module partially failed.

Parameters

Parameter Name Parameter Meaning
EntPhysicalIndex Indicates the index of the entity.
EntPhysicalName Indicates the name of the entity.
EntityTrapFaultID Indicates the error code: 137474.
Reason Indicates a possible cause.

Possible Causes

The fan wind direction was abnormal.

Procedure

  1. Replace the fan.
Translation
Download
Updated: 2019-04-20