Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETRUNK/4/hwMLagConsistencyCheckType2_active

ETRUNK/4/hwMLagConsistencyCheckType2_active

Message

ETRUNK/4/hwMLagConsistencyCheckType2_active: The two switches in the M-LAG have different [typeName] configurations.

Description

The common configuration of M-LAG master and backup devices is inconsistent.

Parameters

Parameter Name Parameter Meaning

[typeName]

Indicates the configuration type. The value must be type2.

Possible Causes

The common configuration of the local or remote device is inconsistent.

Procedure

  • Run the display dfs-group consistency-check { global | interface m-lag m-lag-id } command to check the configuration of M-LAG master and slave devices. Then adjust the deployment based on the check result until the common configuration consistency check succeeds.