Log Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LCS/3/hwGtlItemmismatch_active

LCS/3/hwGtlItemmismatch_active

Message

LCS/3/hwGtlItemmismatch_active: The license item of slot [hwGtlSlotID] mismatched with the main board.

Description

The license control item of the current slot did not match that of the main board.

Parameters

Parameter Name Parameter Meaning

[hwGtlSlotID]

ID of the slot on which the license control item is different from that on the main board

Possible Causes

License files of a stacking system are deployed in distributed mode. That is, each chassis has one license file. When the license files on the master and slave MPUs are different, this log is triggered.

Procedure

  1. Re-upload a license file that is the same as that on the MPU to the server, and activate the file.
  2. Collect log information and contact technical support personnel.