Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Resetting the DLDP Status

Resetting the DLDP Status

Context

After the DLDP status of a disabled interface is reset, the interface re-detects unidirectional links.

When a unidirectional link is detected, the interface enters the Disable state. The system prompts you to shut down the interface or automatically sets the interface state to DLDP Down according to the configuration. To enable the interface to detect unidirectional links again, you can reset the DLDP status of the interface as follows:

  • If the interface is shut down using the shutdown command, run the undo shutdown command to enable the interface to detect unidirectional links again.

  • If the system automatically sets the interface state to DLDP Down, wait the interface to recover using the auto recovery mechanism after the link state becomes bidirectional. You can also run the dldp reset command to reset the DLDP status of the interface.

When you reset the DLDP status globally on a device, the DLDP status is reset for all the disabled ports on the device. When you reset the DLDP status on a disabled interface, the DLDP status is reset only for this interface.

Procedure

  • Reset the DLDP status globally.

    1. Run system-view

      The system view is displayed.

    2. Run dldp reset

      The DLDP status is reset globally.

    3. Run commit

      The configuration is committed.

  • Reset the DLDP status on an interface.

    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The interface view is displayed.

    3. Run dldp reset

      The DLDP status is reset for the interface.

    4. Run commit

      The configuration is committed.