Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R005C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between CFM and VRRP

Configuring Association Between CFM and VRRP

Context

For details about the association, see CFM Association.

Association between CFM and VRRP is bidirectional.

Pre-configuration Tasks

Before configuring association between CFM and VRRP, complete the following tasks:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Configure association based on the usage scenario.

    Table 7-25 Association between CFM and VRRP
    Scenario Configuration 1 Configuration 2

    Bidirectional association between CFM and VRRP

    Run the oam-bind cfm md md-name ma ma-name vrrp vrid vrid interface interface-type interface-number command to configure bidirectional association between CFM and VRRP.

    NOTE:
    If you have run the oam-bind cfm md md-name ma ma-name vrrp vrid vrid interface interface-type interface-number command, the configuration file contains the following commands:
    • oam-bind ingress vrrp vrid vrid interface interface-type interface-number md-name egress cfm md md-name ma ma-name
    • oam-bind ingress cfm md md-name ma ma-name egress vrrp vrid vrid interface interface-type interface-number
    Run either of the following commands:
    • Run the oam-bind ingress vrrp vrid vrid interface interface-type interface-number md-name egress cfm md md-name ma ma-name command to enable VRRP to report faults to CFM.

    • Run the oam-bind ingress cfm md md-name ma ma-name egress vrrp vrid vrid interface interface-type interface-number command to enable CFM to report faults to VRRP.

    Unidirectional association between CFM and VRRP

    Run either of the following commands:
    • Run the oam-bind ingress vrrp vrid egress cfm md md-name ma ma-name command to enable VRRP to report faults to CFM.

    • Run the oam-bind ingress cfm md md-name ma ma-name egress vrrp vrid command to enable CFM to report faults to VRRP.

    None

  4. Run commit

    The configuration is committed.

Translation